Superduty

 
SUPERDUTY
High efficiency coupled with space saving economy
 
 
Superduty will also improve your combination boiler performance - click here.
  Ultra fast recovery of hot water allows for a
reduction in cylinder size. This development has
resulted in the product we know today as the
Superduty, a cylinder used and specified by energy conscious Local Authorities, Housing Associations and private builders alike.
All Albion Superduty cylinders are WRc listed and NHBC approved.

FUEL SAVING
The installation of a Superduty will reduce boiler
operating times and cycling periods resulting in
savings of up to 40% compared with systems using conventional indirect cylinders.

IMPROVES BOILER EFFICIENCY
The effective heat transfer of the Superduty results in very cool primary return temperatures, which maintain the boiler operation on full load - even in the summer months !
This virtually eliminates expensive boiler cycling, a major contribution to fuel saving.
 

SUPERDUTY

 

 
  CF45
  Plenty of hot water for a standard bath and gravity shower in any home.
 
  CF80
  Plenty of hot water for a single bath and pumped shower.
 
  CF120
  Plenty of hot water for larger baths or twin bathroom properties.
Unlike a conventional cylinder which utilises a single 28mm diameter coil, Superduty multicoils are engineered with a manifold which divides into four coiled tubes. This arrangement ensures that far more water is in contact with the copper wall of the heat exchanger, dramatically improving heat transfer between primary and secondary waters.
The Superduty Multicoil heat exchanger is proven to provide cost effective operation and performance, unparalleled in systems of this type.
Just look at the performance graphs!
 
 
Select the product you require and click to view - or click below to access the following information
 
 
 
  900 x 450 British Standard
  Plenty of hot water for a standard bath
and gravity shower in any home.
 
  Superduty CF45
  Plenty of hot water for a single bath
and pumped shower.
 
  Superduty CF80
  Plenty of hot water for larger baths
or twin bathroom properties.

PLENTY OF HOT WATER

 
RECOVERY TIMES (minutes)
BOILER
SIZE
30Kw
24Kw
15Kw
12Kw
9Kw
CF45

4

5
8
10
15

CF80

7

9
15
18
24

CF120

10

12
20
24
30
 
The above recovery times are based on a primary flow of 82°C and a recovery from 20°C through to 60°C. Times quoted are greater than the Albion bench test in order to provide figures which are easily achievable in the home.

A practical example is to compare the hot water available from a CF45 against that from a standard indirect 900 x 450mm cylinder. Using a 15Kw boiler the standard cylinder will deliver approximately 175 litres of hot water per hour (based on 40minutes recovery). The Superduty CF45 will produce approximately 340 litres in these circumstances
(8 minutes recovery).
 
   
   

SUPERDUTY

 
   
Superduty Cisternflow cylinders are suitable for fully pumped primary systems fuelled from mains gas, lpg or oil boilers.
They are compatible with W, Y and S plan systems.
Quicker re-heat times are acheived with W plan systems.
A probe type insertion thermostat is required to provide increased temperature sensing and accuracy over that of the strap-on type.
A connection is provided on each Superduty for this fitment.
 

PRIMARY CONNECTIONS
CF45 to CF140 22mm compression
All other sizes 1" male B.S.P. Albitec compliant

SECONDARY CONNECTION
CF45 to CF140 22mm compression
All other sizes 1" female B.S.P.
Secondary return: standard 22mm compression on all sizes
120 litre and above.

THERMOSTAT CONNECTION
1/2" female B.S.P. to all models.

IMMERSION HEATER CONNECTION
2 1/4" BSP female in all models.

MAXIMUM WORKING HEAD
10 metres, all models, (15 & 25 metre working head
available to order).

INSULATION
Albion Ecofoam CFC free.

COMBINATION UNITS
All Cisternflow models are available in combination
tank form supplied with byelaw 30 kits and lids.
CF45, CF80, and CF120 litre units have
20 litres of cold storage.
CF140, CF160, CF180 and CF210 litres units have
40 litres of cold storage.

GUARANTEE
Superduty cylinders are guaranteed for 5 years.

SUPERDUTY COMBINATION UNITS

 
   
 
CF COMBI SIZES
CF45 COMBI
950 x 350 mm
CF80 COMBI

995 x 400 mm

CF120 COMBI

1250 x 450 mm

CF140 COMBI

1400 x 450 mm

CF160 COMBI

1550 x 450 mm

CF180 COMBI

1700 x 450 mm

CF210 COMBI

1850 x 450 mm

 
 
 

PRESSURE DROP ON SUPERDUTY COIL

 
   
Flowrate through coil
PRESSURE DROP
(kpa)
L/S
L/M
0.05
3.0
1.0
0.10
6.0
3.3
0.15
9.0
6.4
0.20
12.0
10.5
0.25
15.0
14.2
0.30
18.0
20.9
0.35
21.0
28.2
0.40
24.0
37.0
0.45
27.0
47.3
0.50
30.0
58.0
0.55
33.0
70.5
 
   
THE GREEN ISSUE
 
   
All Superduty cylinders are insulated with a CFC free factory applied insulation unique to Albion.
In addition there is a reduction in boiler emissions into the atmosphere due to reduced boiler operating times and cycling periods.
 
   
CONDENSING BOILERS
 
   
Cool return temperatures and full load demand are particularly beneficial to condensing boilers, keeping them in condensing mode during water heating cycles.  
   
SHOWERFLANGE
 
   
 
Showerflange is particularly suited to Superduty where the use of an immersion heater is not recommended.
The Flange converts a 2 1/4" Heater Boss into a 22mm compression fitting for a bespoke shower connection.
 
 
IMPROVE YOUR HOT WATER FLOW USING ALBION SUPERDUTY
WITH YOUR EXISTING COMBI.
 
The energy efficient Superduty CF45 measures
only 600mm x 350mm yet provides ample hot
water for a standard 1700mm bath.
Coupled with your existing combination boiler you can enjoy a bath full of hot water in just a few minutes.
Bigger bath? No problem - Superduty is available in larger sizes. In addition, all sizes are available with built in cold tanks if a tank-free loft is required - ask for Superduty combination units.
 
SUPERDUTY FOR OPEN VENTED HOT WATER
 
 
   