SUPERDUTY
High efficiency coupled with space saving economy
             
                 
                                             
                                             
   

Superduty will also improve your combination boiler performance - click here.

  Ultra fast recovery of hot water allows for a
reduction in cylinder size. This development has
resulted in the product we know today as the
Superduty, a cylinder used and specified by energy conscious Local Authorities, Housing Associations and private builders alike. All Albion Superduty cylinders are WRc listed and NHBC approved.

FUEL SAVING
The installation of a Superduty will reduce boiler
operating times and cycling periods resulting in
savings of up to 40% compared with systems using conventional indirect cylinders.

IMPROVES BOILER EFFICIENCY
The effective heat transfer of the Superduty results in very cool primary return temperatures, which maintain the boiler operation on full load - even in the summer months !
This virtually eliminates expensive boiler cycling, a major contribution to fuel saving.
             
                   
                   
                   
                   
                   
                   
                   
                   
                   
                                   
   
SUPERDUTY
                               
                       
                                                   
       

Unlike a conventional cylinder which utilises a
single 28mm diameter coil, Superduty multicoils
are engineered with a manifold which divides into
four coiled tubes. This arrangement ensures that
far more water is in contact with the copper wall of the heat exchanger, dramatically improving heat
transfer between primary and secondary waters.
The Superduty Multicoil heat exchanger is proven
to provide cost effective operation and
performance, unparalleled in systems of this type.
Just look at the performance graphs!

SUPERDUTY EXCEEDS THE NEW 'PART L' OF THE BUILDING REGULATIONS.

                   
               
                               
      These tests were carried out in 1996
using a draw off profile devised by BSRIA
                       
   
SUPERDUTY
                   
                                                               
     

PRIMARY CONNECTIONS
CF45 to CF140 22mm compression
All other sizes 1" male B.S.P. Albitec compliant

SECONDARY CONNECTION
CF45 to CF140 22mm compression
All other sizes 1" female B.S.P.
Secondary return: standard 22mm compression on all sizes
120 litre and above.

THERMOSTAT CONNECTION
1/2" female B.S.P. to all models.

IMMERSION HEATER CONNECTION
2 1/4" BSP female in all models.

MAXIMUM WORKING HEAD
10 metres, all models, (15 & 25 metre working head
available to order).

INSULATION
Albion Ecofoam CFC free.

COMBINATION UNITS
All Cisternflow models are available in combination
tank form supplied with byelaw 30 kits and lids.
CF45, CF80, and CF120 litre units have
20 litres of cold storage.
CF140, CF160, CF180 and CF210 litres units have
40 litres of cold storage.

GUARANTEE
Superduty cylinders are guaranteed for five years.

     
  The above recovery times are based on a primary flow of 82°C and a recovery from 20°C through to 60°C. Times quoted are greater than the Albion bench test in order to provide figures which are easily achievable in the home.

A practical example is to compare the hot water available from a CF45 against that from a standard indirect 900 x 450mm cylinder. Using a 15Kw boiler the standard cylinder will deliver approximately 175 litres of hot water per hour (based on 40minutes recovery). The Superduty CF45 will produce approximately 340 litres in these circumstances
(8 minutes recovery).
   
     
THE GREEN ISSUE
                 
                                                               
      All Superduty cylinders are insulated with a CFC free factory applied insulation unique to Albion.
In addition there is a reduction in boiler emissions into the atmosphere due to reduced boiler operating times and cycling periods.
               
             
                                                       
       
CONDENSING BOILERS
       
                                                       
      Cool return temperatures and full load demand are particularly beneficial to condensing boilers, keeping them in condensing mode during water heating cycles.        
     
SHOWERFLANGE
         
                                                               
                                             
     

Showerflange is particularly suited to Superduty where the use of an immersion heater is not recommended.
The Flange converts a 2 1/4" Heater Boss into a 22mm compression fitting for a bespoke shower connection.